Skip to content

--factory-reset-device and --factory-reset fail with "Expected an int, got a boolean" (v2.7.8) #920

Description

@michael-firebotlabs

Describe the bug

Running --factory-reset-device fails immediately with:

Field meshtastic.protobuf.AdminMessage.factory_reset_device: Expected an int, got a boolean.

To Reproduce

meshtastic --factory-reset-device

Expected behavior

Device receives the factory reset command and reboots with cleared BLE bonds and default config.

Root cause

In node.py, factoryReset() assigns Python booleans to protobuf fields that are typed as builtins.int in the generated stubs (admin_pb2.pyi):

p.factory_reset_device = True # raises TypeError in strict protobuf
p.factory_reset_config = True # same issue

Fix

p.factory_reset_device = 1
p.factory_reset_config = 1

Environment

  • meshtastic-python version: 2.7.8
  • Hardware: RAK4631
  • OS: macOS, Python 3.14
  • Connected via: USB serial