I'm testing Redis, StackExchange.Redis, and Redis-Sentinel in order to setup a appropriate HA environment.

I've noticed that when i stand up a sentinel cluster as described in these docs: https://hub.docker.com/r/bitnami/redis-sentinel/ and i shutdown the master after a multiplexer connection has been successfully established by a client using StackExchange.Redis. The multiplexer fails to realize that the failover has occurred and continues to queue messages for the now non-existent leader.

Funny thing is If i manually trigger a failover using the sentinel-cli with SENTINEL FAILOVER mymaster the multiplexer realizes the change and appropriately updates the leader.

I looked into the code and noticed that the +switch-master subscription hook is never fired when the primary Redis is shutdown even if the sentinel associated is still up and running. In the situation where i manually trigger the failover, the hook properly fires.

if (sub.SubscribedEndpoint(RedisChannel.Literal("+switch-master")) == null)
{
sub.Subscribe(RedisChannel.Literal("+switch-master"), (__, message) =>
{
string[] messageParts = ((string)message!).Split(new[] { ' ' }, StringSplitOptions.RemoveEmptyEntries);
// We don't care about the result of this - we're just trying
_ = Format.TryParseEndPoint(string.Format("{0}:{1}", messageParts[1], messageParts[2]), out var switchBlame);
lock (sentinelConnectionChildren)
{
// Switch the primary if we have connections for that service
if (sentinelConnectionChildren.ContainsKey(messageParts[0]))
{
ConnectionMultiplexer child = sentinelConnectionChildren[messageParts[0]];
// Is the connection still valid?
if (child.IsDisposed)
{
child.ConnectionFailed -= OnManagedConnectionFailed;
child.ConnectionRestored -= OnManagedConnectionRestored;
sentinelConnectionChildren.Remove(messageParts[0]);
}
else
{
SwitchPrimary(switchBlame, sentinelConnectionChildren[messageParts[0]]);
}
}
}
}, CommandFlags.FireAndForget);
}

I've confirmed that the sentinel is still issuing the +switch-master command in both scenarios.

I've tried multiple ways to setup the multiplexer, here is my last iteration.

var opts = new ConfigurationOptions
            {
                SyncTimeout = 60000,
                AbortOnConnectFail = false,
                Ssl = false,
                Password = config.Password,
                ReconnectRetryPolicy = new LinearRetry(2000),
                ConnectRetry = 30,
                ServiceName = "mymaster",
                ConfigCheckSeconds = 10
            };
            opts.EndPoints.Add("redis-sentinel-1", 26379);
            opts.EndPoints.Add("redis-sentinel-2", 26379);
            opts.EndPoints.Add("redis-sentinel-3", 26379);

            var log = new LoggerWriter(_log, LogLevel.Information);

            //_multiplexer = await ConnectionMultiplexer.ConnectAsync(opts, log);
            _multiplexerSentinel = await ConnectionMultiplexer.SentinelConnectAsync(opts, log);
            _multiplexer = _multiplexerSentinel.GetSentinelMasterConnection(opts, log);


            _multiplexerSentinel.ConfigurationChanged += (s, e) =>
            {
                _log.LogError($"Sentinel configuration changed (Sentinel): {e.EndPoint}");
                _log.LogInformation($"New server status: {_multiplexerSentinel.GetStatus()}");
            };
            _multiplexerSentinel.ConnectionFailed += (s, e) =>
            {
                _log.LogError($"Connection failed (Sentinel): {e.ConnectionType}, {e.FailureType}, {e.EndPoint}, {e.Exception}");
                _log.LogInformation($"New server status: {_multiplexerSentinel.GetStatus()}");
            };
            _multiplexerSentinel.ConnectionRestored += (s, e) =>
            {
                _log.LogError($"Connection restored (Sentinel): {e.ConnectionType}, {e.FailureType}, {e.EndPoint}, {e.Exception}");
                _log.LogInformation($"New server status: {_multiplexerSentinel.GetStatus()}");
            };
            _multiplexerSentinel.ConfigurationChangedBroadcast += (s, e) =>
            {
                _log.LogError($"Connection changed via broadcast (Sentinel): {e.EndPoint}");
                _log.LogInformation($"New server status: {_multiplexerSentinel.GetStatus()}");
            };

            _multiplexer.ConfigurationChanged += (s, e) =>
            {
                _log.LogError($"Configuration changed: {e.EndPoint}");
                _log.LogInformation($"New server status: {_multiplexer.GetStatus()}");
                //var info = _multiplexer.GetServers().Where(x => x.IsConnected).Select(x => x.InfoRaw()).ToArray();
               // _multiplexer.Configure(new LoggerWriter(_log, LogLevel.Information));
                //_log.LogInformation($"Server info: {info}");
                // _multiplexer.PublishReconfigure();
            };
            _multiplexer.ConnectionFailed += (s, e) =>
            {
                _log.LogError($"Connection failed: {e.ConnectionType}, {e.FailureType}, {e.EndPoint}, {e.Exception}");
                _log.LogInformation($"New server status: {_multiplexer.GetStatus()}");
            };
            _multiplexer.ConnectionRestored += (s, e) =>
            {
                _log.LogError($"Connection restored: {e.ConnectionType}, {e.FailureType}, {e.EndPoint}, {e.Exception}");
                _log.LogInformation($"New server status: {_multiplexer.GetStatus()}");
            };
            _multiplexer.ConfigurationChangedBroadcast += (s, e) =>
            {
                _log.LogError($"Connection changed via broadcast: {e.EndPoint}");
                _log.LogInformation($"New server status: {_multiplexer.GetStatus()}");
            };

Activity

  1. Kilowhisky commented on Jun 22, 2023

    @Kilowhisky
    Author

    This workaround works but its more than a bit hacky...

    My failover period is 20 seconds so 30 should be enough time to elect a new leader.

                var reconfiguring = false;
                _multiplexer.ConnectionFailed += (s, e) =>
                {
                    _log.LogError($"Connection failed: {e.ConnectionType}, {e.FailureType}, {e.EndPoint}, {e.Exception}");
    
                    _ = Task.Run(async () =>
                    {
                        try
                        {
                            if (reconfiguring) return;
                            reconfiguring = true;
                            await Task.Delay(TimeSpan.FromSeconds(30));
                            await _multiplexer.ReconfigureAsync("connection_lost");
                            await _multiplexer.PublishReconfigureAsync();
                            await Task.Delay(TimeSpan.FromSeconds(5));
                            _log.LogInformation($"Reconfigured status: {_multiplexer.GetStatus()}");
                        }finally { reconfiguring = false; }
                    });
                };
    
  2. NickCraver commented on Jul 2, 2023

    @NickCraver
    Collaborator

    The intended usage for Sentinel today is to connect to the sentinel endpoints with a service name, and the ConnectionMultiplexer you get back will be connected to the current primary. When the primary switches, it'll follow (there are 2 multiplexers under the covers, with 1 listening to Sentinel).

    It looks like you may have tried this given the commented out line in code there looking to do this. What was or wasn't happening with that setup and nothing else?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions