@gon0

The NSPanel's temperature sensor is quite noisy and picks up temperature increases from the active display.

However, these issues can probably be tackled:

With all these issues reduced or resolved, the NSPanel could be used for a stand-alone floor-heating/HVAC control.

I propose that the NSPanel could switch one relay on or off with a hysteresis around a temperature setpoint. So a floor-heating is controlled by the temperature, independently from WiFi/HomeAssistant Server/other control systems.

I could imagine, that the following values could be set from Home Assistant:

  • temperature setpoint: relay on (the target temperature, which switches the relay on), e.g. 18 °C
  • temperature setpoint: relay off (the target temperature, which switches the relay off), e.g. 20 °C
  • time duration for relay change (the duration, how long the actual (mean) temperature value should be below "temperature setpoint: relay on" or above "temperature setpoint: relay off")

Once set, the NSPanel could function as a stand-alone unit (probably not as reliable as other units on the market), but probably one of the cheapest solutions which I would trust to leave the flat for a few days without worrying + internet-controlled heating without costly premium brand solutions with an additional bride like BOSCH..etc.

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

Labels

Ready for next releaseThis issue has been fixed/implemented and is ready to go out in next release.enhancementNew feature or request

Projects

No projects

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions